Shop Fashion & Beauty Products In Abuja

Hand-Held Refractometer REF-H2 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Hand-Held Refractometer REF-H2 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Hand-Held Refractometer REF-H2 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES HAND-HELD REFRACTOMETER Art.No. REF-H2 REF-H90A REF-H32 REF-H80 Can supply all the specifications according to customer's request We are your One Stop Hub for Medical Equipment | Hospital Supplies | Lab Consumables | Surgical Instruments | Dental Care | Clinical Devices | PPE Ki
Abuja    17-10-2022
On Request
Flame Photometer FP-640A IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Flame Photometer FP-640A IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Flame Photometer FP-640A IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES FLAME PHOTOMETER Art.No. FP-640A Stability: Indictor drift≤2% Reproductivity: Indicator drift≤2.5% Linear error: K 0.02-0.07 mmol/L. Na 1.1-1.6 mmol/L We are your One Stop Hub for Medical Equipment | Hospital Supplies | Lab Consumables | Surgical Instruments | Dental Care | Clinic
Abuja    17-10-2022
On Request
 
Don't miss the best deals!
 

In creating an alert, you'll stay up to date by receiving the latest deals directly in your inbox.

It's free and require only few seconds!

 
Flame Photometer FP-640D IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Flame Photometer FP-640D IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Flame Photometer FP-640D IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES FLAME PHOTOMETER Art.No. FP-640D Receiving part Photocell Spectral mode Interference filter Display mode Dual channel digital display Linear range K: 0.02-0.07mmol/L Na: 1.10-1.60mmol/L Representitiveness Cv≤2% We are your One Stop Hub for Medical Equipment | Hospital Supplies | Lab
Abuja    17-10-2022
On Request
Flame Photometer FP-640NC IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Flame Photometer FP-640NC IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Flame Photometer FP-640NC IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES FLAME PHOTOMETER Art.No. FP-640NC Sensitivity K:0.01ppm; Na:0.01ppm Measuring range K:0-100ppm; Na:0-160ppm Linearity K:0.195ppm(0.39-3.12)ppm Na:0.69ppm(1.15-9.2)ppm Repeatability 1% CV for 20 consecutive samples Calculation automatic We are your One Stop Hub for Medical Equipment |
Abuja    17-10-2022
On Request
Gas Chromatograph GC-Y112 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Gas Chromatograph GC-Y112 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Gas Chromatograph GC-Y112 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES GAS CHROMATOGRAPH Art.No. GC-Y112 Temperature range Oven: Room temperature5 - 400 Injector:Room temperature7 - 420 Detector FID or TCD Specification 7-inch color touch screen Optional accessories N2000 chromatograph workstation We are your One Stop Hub for Medical Equipment | Hospita
Abuja    17-10-2022
On Request
Gas Chromatograph GC-Y102 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Gas Chromatograph GC-Y102 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Gas Chromatograph GC-Y102 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES GAS CHROMATOGRAPH Art.No. GC-Y102 Operation PC control Temperature range 15-399(increment 1) detector sigle FID Detection limit Dt≤1×10-10g/s (hexadecane) Baseline drift ≤2×10-12A/h Optional accessories N2000 chromatograph workstation We are your One Stop Hub for Medical Equipm
Abuja    17-10-2022
On Request
Gas Chromatograph GC-H1120A IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Gas Chromatograph GC-H1120A IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Gas Chromatograph GC-H1120A IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES GAS CHROMATOGRAPH Art.No. GC-H1120A (GC+SPL+FID) Art.No. GC-H1120B (GC+SPL+PIP+2xFID) Art.No. GC-H1120C (GC+SPL+2xPIP+2xFID+Software Specifications Column oven Temperature range: Ambient temperature +7-400(increment 1) Temperature control accuracy:better than 0.1 Temperature progra
Abuja    17-10-2022
On Request
Atomic Absorption Spectrophotometer AAS-320 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Atomic Absorption Spectrophotometer AAS-320 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Atomic Absorption Spectrophotometer AAS-320 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES ATOMIC ABSORPTION SPECTROPHOTOMETER (AAS) Art.No. AAS-320 Working spectral range 190~900nm Wavelength accuracy ≤±0.5nm Wavelength repeatability ≤0.3nm (single direction) Spectrum bandwidth 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm Resolution <40% Base line st
Abuja    17-10-2022
On Request
Atomic Absorption Spectrophotometer AAS-3520 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Atomic Absorption Spectrophotometer AAS-3520 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Atomic Absorption Spectrophotometer AAS-3520 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES ATOMIC ABSORPTION SPECTROPHOTOMETER (AAS) Art.No. AAS-3520 Monochrometer Achromatic C-T Grating 1200mm Wavelength range 190~900nm Wavelength accuracy ≤±0.2nm Wavelength repeatability ≤0.1nm Spectrum bandwidth 0.1, 0.2, 0.7, 1.4 nm Adjustable Precision RSD≤1%
Abuja    17-10-2022
On Request
Atomic Absorption Spectrophotometer AAS-3530 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Atomic Absorption Spectrophotometer AAS-3530 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Atomic Absorption Spectrophotometer AAS-3530 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES ATOMIC ABSORPTION SPECTROPHOTOMETER (AAS) Art.No. AAS-3530 Monochrometer Achromatic C-T Grating 1800mm Wavelength range 190~900nm Wavelength accuracy ≤±0.2nm Wavelength repeatability ≤0.1nm Spectrum bandwidth 0.1, 0.2, 0.7, 1.4 nm Adjustable Precision RSD≤1%
Abuja    17-10-2022
On Request
HPLC LC-H162A IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-H162A IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-H162A IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES HPLC LC162A (pump+detector+injector+column) Main configuration High pressure constant flow pump P1620A Flow rate range: [***] ml/min RSD: ≤0.08% (1ml/min, water) Peak operating pressure: 45MPa Leakproofness pressure drop:<0.3MPa/10min (45MPa) Variable wavelength ultraviolet detector UV1620A
Abuja    17-10-2022
On Request
HPLC LC-H162B IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-H162B IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-H162B IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES HPLC LC-D110A (pump+detector+injector+column) Main configuration High pressure constant flow pump P1100 Flow Range0.001mL/min-10.000mL/min; Flow Accuracy≤±0.3% (1.00ml/min, H2O,R.T.,8.5MPa) Flow stabilityRSD≤0.1% (1.00ml/min, H2O,R.T.,8.5MPa) Maximum Pressure42MPa UV/VIS Detector D1100 Wave
Abuja    17-10-2022
On Request
HPLC LC-D110A IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-D110A IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-D110A IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES HPLC LC-D110A (pump+detector+injector+column) Main configuration High pressure constant flow pump P1100 Flow Range0.001mL/min-10.000mL/min; Flow Accuracy≤±0.3% (1.00ml/min, H2O,R.T.,8.5MPa) Flow stabilityRSD≤0.1% (1.00ml/min, H2O,R.T.,8.5MPa) Maximum Pressure42MPa UV/VIS Detector D1100 Wave
Abuja    17-10-2022
On Request
HPLC LC-D110B IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-D110B IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-D110B IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES HPLC LC-D110B (2pumps+detector+injector+column+mixer) Main configuration High pressure constant flow pump P1100 Flow Range0.001mL/min-10.000mL/min; Flow Accuracy≤±0.3% (1.00ml/min, H2O,R.T.,8.5MPa) Flow stabilityRSD≤0.1% (1.00ml/min, H2O,R.T.,8.5MPa) Maximum Pressure42MPa UV/VIS Detector D1
Abuja    17-10-2022
On Request
HPLC LC-W100B IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-W100B IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-W100B IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES HPLC LC-W100B (2pumps+detector+injector+column+mixer) Main Configuration High pressure constant flow pump LC-100 PLUS Flow rate Range: [***] mL/min RSD<0.06% Peak Operating Pressure:42MPa Pressure Pulsation<0.1MPa Variable wavelength ultraviolet detector LC-UV100 PLUS Wavelength Range:190-
Abuja    17-10-2022
On Request
HPLC LC-W100AN IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-W100AN IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-W100AN IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES HPLC LC-W100AN (pump+detector+injector+column) Main Configuration High pressure constant flow pump LC-100 PLUS Flow rate Range: [***] mL/min RSD<0.06% Peak Operating Pressure:42MPa Pressure Pulsation<0.1MPa Variable wavelength ultraviolet detector LC-UV100 PLUS Wavelength Range:190-680nm
Abuja    17-10-2022
On Request
HPLC LC-W100BN IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-W100BN IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

HPLC LC-W100BN IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES HPLC LC-W100BN (2pumps+detector+injector+column+mixer) Main Configuration High pressure constant flow pump LC-100 PLUS Flow rate Range: [***] mL/min RSD<0.06% Peak Operating Pressure:42MPa Pressure Pulsation<0.1MPa Variable wavelength ultraviolet detector LC-UV100 PLUS Wavelength Range:19
Abuja    17-10-2022
On Request
Amino Acid Liquid Chromatography LC-AA98 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Amino Acid Liquid Chromatography LC-AA98 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

Amino Acid Liquid Chromatography LC-AA98 IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES Amino Acid Liquid Chromatography LC-AA98 / LC-AA98AT Main configuration Unit Quantity SEMI AUTO P98I Binary Gradient Pump set 1 - - a. Operating pressure: 042MPa (6000 psi) maximum. b. Flow rate range: 0.00110ml/minc. Flow rate precision: ±1% d. Flow rate accuracy: 25
Abuja    17-10-2022
On Request
DENTAL BRUSH APPLICATOR DIVIDER IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

DENTAL BRUSH APPLICATOR DIVIDER IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

DENTAL BRUSH APPLICATOR DIVIDER IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES We are your One Stop Hub for Medical Equipment | Hospital Supplies | Lab Consumables | Surgical Instruments | Dental Care | Clinical Devices | PPE Kits | Disinfectants | Consumables & Disposables |Lab Diagnostics & Instruments | Medical Device & Equipment |Medical I
Abuja    11-10-2022
On Request
AIR WATER SYRINGE IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

AIR WATER SYRINGE IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES

AIR WATER SYRINGE IN NIGERIA BY SCANTRIK MEDICAL SUPPLIES The air water syringe tip is the item that is used to spray air and water in a patient’s mouth during a dental treatment. Due to it’s simplicity, a dentist orthodontist, and hygienist overlook the cross-contamination ramifications that can occur from not properly sterilizing their metal
Abuja    11-10-2022
On Request